Products

Regulations

JIS Standard

Code
Description
Phase
Column Size
Cat.No.
K 0088
Methods for determination of benzene in flue gas
InertCap 1
0.25 mm
I.D.×60 m
df=0.40 μm
1010-11163
InertCap 5
0.25 mm
I.D.×60 m
df=0.40 μm
1010-18163
K 0089
Methods for determination of acrolein in flue gas
InertCap Pure-WAX
0.32 mm
I.D.×60 m
df=0.50 μm
1010-68264
InertCap WAX
0.32 mm
I.D.×60 m
df=0.50 μm
1010-67264
K 0093
Methods for determination of polychlorinated biphenyl in industrial waste water
InertCap 1
0.25 mm
I.D.×60 m
df=0.25 μm
1010-11162
InertCap 5
0.25 mm
I.D.×60 m
df=0.25 μm
1010-18162
K 0108
Methods for determination of hydrogen sulfide in flue gas
InertCap 1
0.25 mm
I.D.×60 m
df=1.50 μm
1010-11166
K 0125
Testing methods for volatile organic compounds in industrial water and waste water
InertCap AQUATIC
0.25 mm
I.D.×60 m
df=1.00 μm
1010-29165
K 0128
Testing methods for pesticides of industrial water and waste water
InertCap 1MS
0.25 mm
I.D.×30 m
df=0.25 μm
1010-12142
InertCap 5MS/Sil
0.25 mm
I.D.×30 m
df=0.25 μm
1010-15142
InertCap 5MS/NP
0.25 mm
I.D.×30 m
df=0.25 μm
1010-18642
K 0303
Methods for determination of formaldehyde in flue gas
InertCap 17
0.25 mm
I.D.×30 m
df=0.25 μm
1010-65142
K 0400-28-20
Water quality Determination of selected monovalent phenols-- Part 1 Gas-chromatographic method after enrichment by extraction
InertCap 5
0.25 mm
I.D.×30 m
df=0.25 μm
1010-18142
InertCap 1701
0.25 mm
I.D.×30 m
df=0.25 μm
1010-61142
InertCap 225
0.25 mm
I.D.×30 m
df=0.25 μm
1010-66642
InertCap FFAP
0.25 mm
I.D.×30 m
df=0.25 μm
1010-28642
K 0450-10-10
Testing methods for bisphenol A in industrial water and waste water
InertCap 1MS
0.25 mm
I.D.×30 m
df=0.25 μm
1010-12142
K 0450-20-10
Testing methods for alkyl phenol in industrial water and waste water
InertCap 1MS
0.25 mm
I.D.×30 m
df=0.25 μm
1010-12142
K 0450-30-10
Testing methods for phthalic acid esters in industrial water and waste water
InertCap 1MS
0.25 mm
I.D.×30 m
df=0.25 μm
1010-12142
K 0450-40-10
Testing method for hexanedioic acid bis(2-ethyhexyl) ester in industrial water and wastewater
InertCap 5MS/Sil
0.25 mm
I.D.×30 m
df=0.25 μm
1010-15142
InertCap 5MS/NP
0.25 mm
I.D.×30 m
df=0.25 μm
1010-18642
K 0450-50-10
Testing method for benzophenone in industrial water and wastewater
InertCap 5MS/Sil
0.25 mm
I.D.×30 m
df=0.25 μm
1010-15142
InertCap 5MS/NP
0.25 mm
I.D.×30 m
df=0.25 μm
1010-18642
K 0450-60-10
Testing method for individual 4-nonylphenol isomers in industrial water and wastewater
InertCap 5MS/Sil
0.25 mm
I.D.×30 m
df=0.25 μm
1010-15142
InertCap 5MS/NP
0.25 mm
I.D.×30 m
df=0.25 μm
1010-18642
K 1503
Acetone
InertCap Pure-WAX
0.53 mm
I.D.×30 m
df=1.00  μm
1010-68445
InertCap WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-67445
InertCap 17
0.53 mm
I.D.×30 m
df=1.00 μm
1010-65445
K 1522
Isopropyl alcohol (Isopropanol)
InertCap Pure-WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-68162
InertCap WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-67162
InertCap 17
0.25 mm
I.D.×60 m
df=0.25 μm
1010-65162
K 1524
Methyl ethyl ketone
InertCap FFAP
0.25 mm
I.D.×60 m
df=0.25 μm
1010-28662
K 1570
Test methods for determining the effectiveness of wood
preservatives and their performance requirements
InertCap 5
0.32 mm
I.D.×30 m
df=0.25 μm
1010-18242
K 2280
Petroleum products-Determination of octane number, cetane number and calculation of cetane index
InertCap 1
0.25 mm
I.D.×60 m
df=0.25 μm
1010-11162
K 2301
Fuel gases and natural gas—Methods for chemical analysis and testing
InertCap 1
0.25 mm
I.D.×60 m
df=1.50 μm
1010-11166
InertCap 1
0.32 mm
I.D.×60 m
df=5.00 μm
1010-11269
TC-BOND Alumina/KCl
0.32 mm
I.D.×50 m
df=5.00 μm
1010-40125
TC-BOND Q
0.53 mm
I.D.×30 m
df=20.00 μm
1010-40243
K 2435-1
Benzene
InertCap Pure-WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-68162
InertCap WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-67162
K 2435-2
Toluene
InertCap Pure-WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-68162
InertCap WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-67162
K 2435-3
Xylene
InertCap Pure-WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-68162
InertCap WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-67162
K 2536-2
Liquid petroleum products—Testing method of components Part 2: Determination of total components by gas chromatography
InertCap 1
0.20 mm
I.D.×50 m
df=0.25 μm
Please contact
K 2536-3
Liquid petroleum products -
Testing method for components Part 2: Determination of total components by gas chromatography
InertCap Pure-WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-68142
InertCap WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-67142
K 5601-5-1
Testing methods for paint components—Part 5: Determination of volatile organic compound (VOC) content in paints
InertCap 1
0.32 mm
I.D.×50 m
df=1.00 μm
Please contact
K 5601-5-1
Testing methods for paint components—Part 5: Determination of volatile organic compound (VOC) content in paints
InertCap 1
0.20 mm
I.D.×50 m
df=0.2 5 μm
Please contact
InertCap 1
0.32 mm
I.D.×50 m
df=0.25 μm
Please contact
InertCap 1
0.32 mm
I.D.×50 m
df=1.00 μm
Please contact
InertCap Pure-WAX
0.20 mm
I.D.×25 m
df=0.20 μm
Please contact
InertCap WAX
0.20 mm
I.D.×25 m
df=0.20 μm
Please contact
K 6220-3
Rubber compounding ingredients—Organic chemicals—Test methods—Part 3: p-Phenylenediamine antidegradants (PPDs)
InertCap 1
0.25 mm
I.D.×30 m
df=0.25 μm
1010-11142
InertCap 5
0.53 mm
I.D.×15 m
df=3.00 μm
1010-18428
K 6231
Rubber -- Identification of polymers (single polymers and
blends) -- Pyrolytic gas chromatographic method
InertCap 5MS/Sil
0.25 mm
I.D.×30 m
df=1.00 μm
1010-15145
0.25 mm
I.D.×30 m
df=0.25 μm
1010-15142
K 6910
Testing methods for phenolic resins
InertCap Pure-WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-68162
InertCap WAX
0.25 mm
I.D.×60 m
df=0.25 μm
1010-67162
InertCap 5
0.32 mm
I.D.×30 m
df=0.25 μm
1010-18242
InertCap 1701
0.32 mm
I.D.×25 m
Please contact
InertCap 1701
0.53 mm
I.D.×25 m
Please contact
K 8034
Acetone
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8039
Acetonitrile for pesticide residue and polychlorinated biphenyl analysis (Reagent)
InertCap Pure-WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-68142
InertCap WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-67142
K 8040
Acetone for pesticide residue and polychlorinated biphenyl analysis
InertCap Pure-WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-68142
InertCap WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-67142
K 8051
3-Methyl-1-butanol (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8093
Ethanol for pesticide residue and polychlorinated biphenyl analysis
InertCap Pure-WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-68142
InertCap WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-67142
K 8101
Ethanol (99.5)
InertCap 624
0.53 mm
I.D.×30 m
df=3.00 μm
1010-14948
K 8102
Ethanol (95) (Reagent)
InertCap 624
0.32 mm
I.D.×30 m
df=1.80 μm
1010-14747
K 8103
Diethyl ether (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8110
Ethyl acetate for pesticide residue and polychlorinated biphenyl analysis (Reagent)
InertCap 1
0.32 mm
I.D.×30 m
df=5.00 μm
1010-11249
K 8117
Dichloromethane for pesticide residue and polychlorinated biphenyl analysis (Reagent)
InertCap Pure-WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-68142
InertCap WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-67142
K 8161
Dichloromethane (Reagent)
InertCap Pure-WAX/WAX
0.25 mm
I.D.×30 m
df=1.00 μm
Please contact
K 8271
Xylene (Reagent)
InertCap 5
0.53 mm
I.D.×30 m
df=2.00 μm
1010-18447
K 8295
Glycerol (Reagent)
InertCap 624
0.53 mm
I.D.×30 m
df=1.50 μm
Please contact
K 8322
Chloroform
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8355
Acetic acid
InertCap Pure-WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-68445
InertCap WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-67445
K 8357
Diethyl ether for pesticide residue and polychlorinated biphenyl analysis (Reagent)
InertCap 1
0.32 mm
I.D.×30 m
df=5.00 μm
1010-11249
K 8361
Ethyl acetate (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8390
Salicylaldehyde (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=1.50 μm
1010-1446
K 8461
1,4-Dioxane (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8462
Cyclohexanol (Reagent)
InertCap Pure-WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-68445
InertCap WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-67445
K 8463
Cyclohexanone (Reagent)
InertCap Pure-WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-68445
InertCap WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-67445
K 8464
Cyclohexane
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8465
1,2-Dichloroethane (Reagent)
InertCap 1
0.53 mm
I.D.×30 m df=5.00 μm
1010-11449
K 8500
N,N-Dimethylformamide (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8680
Toluene (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8698
1-Naphthol (Reagent)
InertCap 1
0.25 mm
I.D.×30 m
df=0.25 μm
1010-11142
K 8699
2-Naphthol (Reagent)
InertCap 1
0.25 mm
I.D.×30 m
df=0.25 μm
1010-11142
K 8732
Carbon disulfide (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8777
Pyridine
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8798
Phenol (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8810
1-Butanol (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8811
2-Methyl-1-propanol (Reagent)
InertCap Pure-WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-68445
InertCap WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-67445
K 8825
Hexane for pesticide residue and polychlorinated biphenyl analysis (Reagent)
InertCap 1
0.32 mm
I.D.×30 m
df=5.00 μm
1010-11249
K 8839
2-Propanol (Reagent)
InertCap Pure-WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-68445
InertCap WAX
0.53 mm
I.D.×30 m
df=1.00 μm
1010-67445
K 8848
Hexane (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8857
Benzaldehyde (Ragent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8858
Benzene (Reagent)
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8872
Formaldehyde solution (Reagent)
InertCap 1
0.53 mm
I.D.×30 m df=5.00 μm
1010-11449
K 8891
Methanol
InertCap 1
0.53 mm
I.D.×30 m
df=5.00 μm
1010-11449
K 8900
2-Butanone (Reagent)
InertCap Pure-WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-68142
InertCap WAX
0.25 mm
I.D.×30 m
df=0.25 μm
1010-67142
K 9032
Resorcinol (Reagent)
InertCap 1
0.25 mm
I.D.×30 m
df=0.25 μm
1010-11142
K 9523
Nitromethane (Reagent)
InertCap Pure-WAX
0.53 mm
I.D.×15 m
df=1.00 μm
1010-68425
InertCap WAX
0.53 mm
I.D.×15 m
df=1.00 μm
1010-67425
A 1904
SVOC
Determination of the emission of semi volatile organic compounds by building products—Micro chamber method
InertCap 1MS
0.25 mm
I.D.×60 m
df=0.25 μm
1010-12162
InertCap 5MS/Sil
0.25 mm
I.D.×60 m
df=0.25 μm
1010-15162
A 1965
Determination of Volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
InertCap 1MS
0.25 mm
I.D.×60 m
df=0.25 μm
1010-12162

Note) Although 0.5 μm of film thickness capillary column is recommended on JIS Standard, we recommend 5 μm of one for separating methanol and ethanol.