InertSustain NH2 shows far superior stability compared to other brand available aminopropyl columns, as our newly developed "Evolved Surface Silica" is chemically bonded with aminopropyl group. Generally, aminopropyl columns are used for applications that are hard to be separated in a reversed phase mode, such as simultaneous analysis of sugars or vitamin E. However, the shift in retention time has been an issue for a long time. InertSustain NH2 delivers highly reliable reproducibility and stability with accurate qualitative and quantitative results. Furthermore, aminopropyl columns generally cannot be washed by weakly acidic eluent, however InertSustain NH2 was improved and it can be washed by weakly acidic eluent.
Functional Group
Base Material
: High Purity ES Silica Gel
Particle Size
: 3 µm, 5 µm
Surface Area
: 350 m2/g
Pore Size
: 100 Å (10 nm)
Pore Volume
: 0.85 mL/g
Functional Group
: Aminopropyl
End-capping
: None
Carbon Loading
: 7.0 %
USP Code
: L8
pH Range
: 2 - 7.5
InertSustain NH2 Analytical Columns
Particle Size
I.D.
Length
Qty.
Cat.No.
3µm
1.0mm
30mm
1pc
5020-16768
3µm
1.0mm
50mm
1pc
5020-16769
3µm
1.0mm
75mm
1pc
5020-16770
3µm
1.0mm
100mm
1pc
5020-16771
3µm
1.0mm
150mm
1pc
5020-16772
3µm
1.0mm
250mm
1pc
5020-16773
3µm
1.5mm
30mm
1pc
5020-16774
3µm
1.5mm
50mm
1pc
5020-16775
3µm
1.5mm
75mm
1pc
5020-16776
3µm
1.5mm
100mm
1pc
5020-16777
3µm
1.5mm
150mm
1pc
5020-16778
3µm
1.5mm
250mm
1pc
5020-16779
3µm
2.1mm
30mm
1pc
5020-16732
3µm
2.1mm
50mm
1pc
5020-16733
3µm
2.1mm
75mm
1pc
5020-16734
3µm
2.1mm
100mm
1pc
5020-16735
3µm
2.1mm
150mm
1pc
5020-16736
3µm
2.1mm
250mm
1pc
5020-16737
3µm
3.0mm
30mm
1pc
5020-16739
3µm
3.0mm
50mm
1pc
5020-16740
3µm
3.0mm
75mm
1pc
5020-16741
3µm
3.0mm
100mm
1pc
5020-16742
3µm
3.0mm
150mm
1pc
5020-16743
3µm
3.0mm
250mm
1pc
5020-16744
3µm
4.0mm
30mm
1pc
5020-16746
3µm
4.0mm
50mm
1pc
5020-16747
3µm
4.0mm
75mm
1pc
5020-16748
3µm
4.0mm
100mm
1pc
5020-16749
3µm
4.0mm
150mm
1pc
5020-16750
3µm
4.0mm
250mm
1pc
5020-16751
3µm
4.6mm
30mm
1pc
5020-16753
3µm
4.6mm
50mm
1pc
5020-16754
3µm
4.6mm
75mm
1pc
5020-16755
3µm
4.6mm
100mm
1pc
5020-16756
3µm
4.6mm
150mm
1pc
5020-16757
3µm
4.6mm
250mm
1pc
5020-16758
5µm
1.0mm
30mm
1pc
5020-16639
5µm
1.0mm
50mm
1pc
5020-16640
5µm
1.0mm
75mm
1pc
5020-16641
5µm
1.0mm
100mm
1pc
5020-16642
5µm
1.0mm
150mm
1pc
5020-16643
5µm
1.0mm
250mm
1pc
5020-16644
5µm
1.5mm
30mm
1pc
5020-16645
5µm
1.5mm
50mm
1pc
5020-16646
5µm
1.5mm
75mm
1pc
5020-16647
5µm
1.5mm
100mm
1pc
5020-16648
5µm
1.5mm
150mm
1pc
5020-16649
5µm
1.5mm
250mm
1pc
5020-16650
5µm
2.1mm
30mm
1pc
5020-16602
5µm
2.1mm
50mm
1pc
5020-16603
5µm
2.1mm
75mm
1pc
5020-16604
5µm
2.1mm
100mm
1pc
5020-16605
5µm
2.1mm
150mm
1pc
5020-16606
5µm
2.1mm
250mm
1pc
5020-16607
5µm
3.0mm
30mm
1pc
5020-16609
5µm
3.0mm
50mm
1pc
5020-16610
5µm
3.0mm
75mm
1pc
5020-16611
5µm
3.0mm
100mm
1pc
5020-16612
5µm
3.0mm
150mm
1pc
5020-16613
5µm
3.0mm
250mm
1pc
5020-16614
5µm
3.9mm
300mm
1pc
5020-89979
5µm
4.0mm
30mm
1pc
5020-16616
5µm
4.0mm
50mm
1pc
5020-16617
5µm
4.0mm
75mm
1pc
5020-16618
5µm
4.0mm
100mm
1pc
5020-16619
5µm
4.0mm
150mm
1pc
5020-16620
5µm
4.0mm
250mm
1pc
5020-16621
5µm
4.6mm
30mm
1pc
5020-16623
5µm
4.6mm
50mm
1pc
5020-16624
5µm
4.6mm
75mm
1pc
5020-16625
5µm
4.6mm
100mm
1pc
5020-16626
5µm
4.6mm
150mm
1pc
5020-16627
5µm
4.6mm
250mm
1pc
5020-16628
InertSustain NH2 with 100% CH3CN
Below columns are shipped with a 100% Acetonitrile solvent. This can be required when using the column in HILIC-mode. Normal shipping condition is a hexane/ethanol solvent.