Products

HILIC Columns

InertSustain NH2 Analytical Columns

InertSustain NH2 shows far superior stability compared to other brand available aminopropyl columns, as our newly developed "Evolved Surface Silica" is chemically bonded with aminopropyl group. Generally, aminopropyl columns are used for applications that are hard to be separated in a reversed phase mode, such as simultaneous analysis of sugars or vitamin E. However, the shift in retention time has been an issue for a long time. InertSustain NH2 delivers highly reliable reproducibility and stability with accurate qualitative and quantitative results. Furthermore, aminopropyl columns generally cannot be washed by weakly acidic eluent, however InertSustain NH2 was improved and it can be washed by weakly acidic eluent.

化学結合基の画像

Functional Group

Base Material : High Purity ES Silica Gel
Particle Size : 3 µm, 5 µm
Surface Area : 350 m2/g
Pore Size : 100 Å (10 nm)
Pore Volume : 0.85 mL/g
Functional Group : Aminopropyl
End-capping : None
Carbon Loading : 7.0 %
USP Code : L8
pH Range : 2 - 7.5

InertSustain NH2 Analytical Columns

Particle Size
I.D.
Length
Qty.Cat.No.
3µm1.0mm30mm1pc5020-16768
3µm1.0mm50mm1pc5020-16769
3µm1.0mm75mm1pc5020-16770
3µm1.0mm100mm1pc5020-16771
3µm1.0mm150mm1pc5020-16772
3µm1.0mm250mm1pc5020-16773
3µm1.5mm30mm1pc5020-16774
3µm1.5mm50mm1pc5020-16775
3µm1.5mm75mm1pc5020-16776
3µm1.5mm100mm1pc5020-16777
3µm1.5mm150mm1pc5020-16778
3µm1.5mm250mm1pc5020-16779
3µm2.1mm30mm1pc5020-16732
3µm2.1mm50mm1pc5020-16733
3µm2.1mm75mm1pc5020-16734
3µm2.1mm100mm1pc5020-16735
3µm2.1mm150mm1pc5020-16736
3µm2.1mm250mm1pc5020-16737
3µm3.0mm30mm1pc5020-16739
3µm3.0mm50mm1pc5020-16740
3µm3.0mm75mm1pc5020-16741
3µm3.0mm100mm1pc5020-16742
3µm3.0mm150mm1pc5020-16743
3µm3.0mm250mm1pc5020-16744
3µm4.0mm30mm1pc5020-16746
3µm4.0mm50mm1pc5020-16747
3µm4.0mm75mm1pc5020-16748
3µm4.0mm100mm1pc5020-16749
3µm4.0mm150mm1pc5020-16750
3µm4.0mm250mm1pc5020-16751
3µm4.6mm30mm1pc5020-16753
3µm4.6mm50mm1pc5020-16754
3µm4.6mm75mm1pc5020-16755
3µm4.6mm100mm1pc5020-16756
3µm4.6mm150mm1pc5020-16757
3µm4.6mm250mm1pc5020-16758
5µm1.0mm30mm1pc5020-16639
5µm1.0mm50mm1pc5020-16640
5µm1.0mm75mm1pc5020-16641
5µm1.0mm100mm1pc5020-16642
5µm1.0mm150mm1pc5020-16643
5µm1.0mm250mm1pc5020-16644
5µm1.5mm30mm1pc5020-16645
5µm1.5mm50mm1pc5020-16646
5µm1.5mm75mm1pc5020-16647
5µm1.5mm100mm1pc5020-16648
5µm1.5mm150mm1pc5020-16649
5µm1.5mm250mm1pc5020-16650
5µm2.1mm30mm1pc5020-16602
5µm2.1mm50mm1pc5020-16603
5µm2.1mm75mm1pc5020-16604
5µm2.1mm100mm1pc5020-16605
5µm2.1mm150mm1pc5020-16606
5µm2.1mm250mm1pc5020-16607
5µm3.0mm30mm1pc5020-16609
5µm3.0mm50mm1pc5020-16610
5µm3.0mm75mm1pc5020-16611
5µm3.0mm100mm1pc5020-16612
5µm3.0mm150mm1pc5020-16613
5µm3.0mm250mm1pc5020-16614
5µm3.9mm300mm1pc5020-89979
5µm4.0mm30mm1pc5020-16616
5µm4.0mm50mm1pc5020-16617
5µm4.0mm75mm1pc5020-16618
5µm4.0mm100mm1pc5020-16619
5µm4.0mm150mm1pc5020-16620
5µm4.0mm250mm1pc5020-16621
5µm4.6mm30mm1pc5020-16623
5µm4.6mm50mm1pc5020-16624
5µm4.6mm75mm1pc5020-16625
5µm4.6mm100mm1pc5020-16626
5µm4.6mm150mm1pc5020-16627
5µm4.6mm250mm1pc5020-16628

InertSustain NH2 with 100% CH3CN

Below columns are shipped with a 100% Acetonitrile solvent. This can be required when using the column in HILIC-mode. Normal shipping condition is a hexane/ethanol solvent.

InertSustain NH2 with 100% CH3CN

Particle Size
I.D.
Length
Qty.
Cat.No.
5µm4.0mm150mm1pc5020-89954
5µm4.0mm250mm1pc5020-89955
5µm4.6mm150mm1pc5020-89950
5µm4.6mm250mm1pc5020-89951