Products

HILIC Columns

Inertsil NH2 Analytical Columns

Inertsil NH2 shows far superior stability compared to other brand available aminopropyl columns, as our newly developed "Evolved Surface Silica" is chemically bonded with aminopropyl group. Generally, aminopropyl columns are used for applications that are hard to be separated in a reversed phase mode, such as simultaneous analysis of sugars or vitamin E. However, the shift in retention time has been an issue for a long time. Inertsil NH2 delivers highly reliable reproducibility and stability with accurate qualitative and quantitative results. Furthermore, aminopropyl columns generally cannot be washed by weakly acidic eluent, however Inertsil NH2 was improved and it can be washed by weakly acidic eluent.

化学結合基の画像

Functional Group

Base Material : 3 Series High Purity Silica Gel
Particle size : 3 µm, 5 µm
Surface Area : 450 m2/g
Pore Size : 100 Å (10 nm)
Pore Volume : 1.05 mL/g
Functional Group : Aminopropyl
End-capping : None
Carbon Loading : 8.0 %
USP Code : L8
pH Range : 2 - 7.5

Inertsil NH2 Analytical Columns

Particle Size
I.D.
Length
Qty.Cat.No.
3µm1.0mm33mm1pc5020-85531
3µm1.0mm50mm1pc5020-85532
3µm1.0mm75mm1pc5020-85533
3µm1.0mm100mm1pc5020-85534
3µm1.0mm150mm1pc5020-85535
3µm1.0mm250mm1pc5020-85536
3µm1.5mm33mm1pc5020-85541
3µm1.5mm50mm1pc5020-85542
3µm1.5mm75mm1pc5020-85543
3µm1.5mm100mm1pc5020-85544
3µm1.5mm150mm1pc5020-85545
3µm1.5mm250mm1pc5020-85546
3µm2.1mm33mm1pc5020-05461
3µm2.1mm50mm1pc5020-05462
3µm2.1mm75mm1pc5020-05463
3µm2.1mm100mm1pc5020-05464
3µm2.1mm150mm1pc5020-05465
3µm2.1mm250mm1pc5020-05466
3µm3.0mm33mm1pc5020-05471
3µm3.0mm50mm1pc5020-05472
3µm3.0mm75mm1pc5020-05473
3µm3.0mm100mm1pc5020-05474
3µm3.0mm150mm1pc5020-05475
3µm3.0mm250mm1pc5020-05476
3µm4.0mm33mm1pc5020-05481
3µm4.0mm50mm1pc5020-05482
3µm4.0mm75mm1pc5020-05483
3µm4.0mm100mm1pc5020-05484
3µm4.0mm150mm1pc5020-05485
3µm4.0mm250mm1pc5020-05486
3µm4.6mm33mm1pc5020-05491
3µm4.6mm50mm1pc5020-05492
3µm4.6mm75mm1pc5020-05493
3µm4.6mm100mm1pc5020-05494
3µm4.6mm150mm1pc5020-05495
3µm4.6mm250mm1pc5020-05496
5µm1.0mm33mm1pc5020-85511
5µm1.0mm50mm1pc5020-85512
5µm1.0mm75mm1pc5020-85513
5µm1.0mm100mm1pc5020-85514
5µm1.0mm150mm1pc5020-85515
5µm1.0mm250mm1pc5020-85516
5µm1.5mm33mm1pc5020-85521
5µm1.5mm50mm1pc5020-85522
5µm1.5mm75mm1pc5020-85523
5µm1.5mm100mm1pc5020-85524
5µm1.5mm150mm1pc5020-85525
5µm1.5mm250mm1pc5020-85526
5µm2.1mm33mm1pc5020-05511
5µm2.1mm50mm1pc5020-05512
5µm2.1mm75mm1pc5020-05513
5µm2.1mm100mm1pc5020-05514
5µm2.1mm150mm1pc5020-05515
5µm2.1mm250mm1pc5020-05516
5µm3.0mm33mm1pc5020-05521
5µm3.0mm50mm1pc5020-05522
5µm3.0mm75mm1pc5020-05523
5µm3.0mm100mm1pc5020-05524
5µm3.0mm150mm1pc5020-05525
5µm3.0mm250mm1pc5020-05526
5µm4.0mm33mm1pc5020-05531
5µm4.0mm50mm1pc5020-05532
5µm4.0mm75mm1pc5020-05533
5µm4.0mm100mm1pc5020-05534
5µm4.0mm150mm1pc5020-05535
5µm4.0mm250mm1pc5020-05536
5µm4.6mm33mm1pc5020-05541
5µm4.6mm50mm1pc5020-05542
5µm4.6mm75mm1pc5020-05543
5µm4.6mm100mm1pc5020-05544
5µm4.6mm150mm1pc5020-05545
5µm4.6mm250mm1pc5020-05546

Inertsil NH2 with 100% CH3CN

Below columns are shipped with a 100% Acetonitrile solvent. This can be required when using the column in HILIC-mode. Normal shipping condition is a hexane/ethanol solvent.

Inertsil NH2 with 100% CH3CN

Particle Size
I.D.
Length
Qty.
Cat.No.
5µm4.6mm150mm1pc5020-89952
5µm4.6mm250mm1pc5020-89953